fn=49: Function 49 Setting Printing Density
GS ( K pL pH fn m
[Code]
<1D>H<28>H<4B>H<pL><pH><fn><m>
[Range]
(pL+pH×256)=2 (pL=2, pH=0)
fn=49
0
≤m≤8, 250≤m≤255
[Default]
m=0 (Customized value setting value)
[Outline]
[The specification which is common to the model]
• Sets printing density.
m
Printing Density
250
Selects density level –6 (70%)
251
Selects density level –5 (75%)
252
Selects density level –4 (80%)
253
Selects density level –3 (85%)
254
Selects density level –2 (90%)
255
Selects density level –1 (95%)
0
Selects standard density (100%)
1
Selects density level + 1 (105%)
2
Selects density level + 2 (110%)
3
Selects density level + 3 (115%)
4
Selects density level + 4 (120%)
5
Selects density level + 5 (125%)
6
Selects density level + 6 (130%)
7
Selects density level + 7 (135%)
8
Selects density level + 8 (140%)