- 466 -
●
MSW1-5
: CR code
[Outline]
Select the printer when receiving CR(<0D>H) code.
OFF(0)
ON(1)
CR mode
Ignored
LF
ON (1) OPERATION:
Select the same operation with LF when receiving CR code.
Print data in print buffer and put linefeeds as specified.
OFF (0) OPERATION:
CR code may be ignored with no actions if receiving CR code.
●
MSW1-6
:
Reserved [Fixed to OFF (0)]
●
MSW1-7
:
DSR signal
[Outline]
Printer can be reset with DSR (serial I/F-6pin) signal. Select enable/disable of reset function with this signal.
OFF(0)
ON(1)
DSR Signal
Invalid
Valid
ON (1) OPERATION: Used as reset signal
OFF (0) OPERATION: Not used as reset signal
●
MSW1-8
:
INIT signal
[Outline]
Printer can be reset with INIT (serial I/F-25Pin) signal. Select enable/disable of reset function with this signal.
OFF(0)
ON(1)
INIT Signal
Invalid
Valid
ON (1) OPERATION: Used as reset signal
OFF (0) OPERATION: Not used as reset signal