Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
- 366 -
fn=97: Function 97 Setting Number of Divisions for Head Conducting
GS ( K pL pH fn m
[Code]
<1D>H<28>H<4B>H<pL><pH><fn><m>
[Range]
(pL+pH×256)=2 (pL=2, pH=0)
fn=97
m=0, 24, 48, 50, 52
[Default]
m=0 (Customized value setting)
[Outline]
[The specification which depend on the model]
CT-S300
/
CT-S310
• Sets the number of divisions for head conducting.
m
No. of Divisions for Head Conducting
0, 48
Selects customized value setting
2, 50
Selects 2-division conducting.
4, 52
Selects 4-division conducting.