GS C ; n1 ; n2 ; n3 ; n4 ; n5 ;
[Function]
Setting the numbering counter mode (B)
[Code]
<1D>H<43>H<3B>H<n1><3B>H<n2><3B>H<n3><3B>H<n4><3B>H<n5><3B>H
<n1>, <n2>, <n3>, <n4>, <n5> are character codes.
[Range]
0
≤n1, n2, n5≤65535
0
≤n3, n4≤255
[Outline]
[The specification which is common to the model]
• This command sets the numbering (serial number counter) mode and a counter value.
n1: First value of ounter range
n2: Last vale of counter range
n3: Counter step value
n4: Identical counter print count
n5: Counter start value
n1<n2: Count-up system
n1>n2: Count-down system
n1=n2 or n3= 0 or n4=0 : Counter stop
[Caution]
[The specification which is common to the model]
• If the n5 counter start value is beyond the counter range specified with n1 and n2, it is assumed to
be n1=n5.
• If each value of n1 through n5 contains the character code other than “0” through “9”, the printer will invalidate
the data up to that parameter and handle the subsequent data as normal data.
[Default]
n1=1, n2=65535, n3=1, n4=1, n5=1