Printer Operation
41
Emulation Auto-Detection
Ordinarily emulation switching is conducted in the Menu Setup mode.
However, switching can also be conducted using the Emulation Auto-
Detection function outlined below.
The following message is displayed on the LCD when the Zebra® emulation
(ZPI2) command is detected during Datamax® emulation.
ZPI2 detected.
Switch
emulation ?
No Yes
By selecting "Yes" the printer will reboot and automatically switch to ZPI2
emulation. The printer will return to the On Line Ready status if "No" is
selected.
The following message is displayed in the LCD when the Datamax®
command is detected during Zebra® emulation.
DMX detected.
Switch
emulation ?
No Yes
By selecting "Yes" the printer will reboot and automatically switch to
Datamax® emulation (DM4/DMI/DPP). The printer will return to the On Line
Ready status if "No" is selected.
Note:
• The Emulation Auto-Detection function will not work if the
"Emulation Auto Detect" command in the Sub Menu in the
"System Setup" in the Top Menu is set to "Off". (The command is
set to "On" when shipped from the factory)
• After the Emulation Auto-Detection function is activated, this
function will not work unless the printer is turned Off and then
turned On again.
• If the "Emulation Auto Detect" function is set to "Full Auto", this
will cause the printer to automatically restart when it detects
an alternative emulation. This is useful for remotely located
machines where the control panel cannot be accessed.
Menu Setup Mode