Printer Adjustments
42
3
Sensor Adjustments and Calibration
The sensing level of both the transparent (see thru) and reflective sensors
is adjusted separately and independently. Firstly, the sensor type must
be selected using the Sensor Method Selection shown below. Then the
adjustment and calibration of the sensor can be made.
Entering Sensor Adjustment Mode
Turn on the power while pushing the PAUSE key, FEED key,
11
and STOP key simultaneously1
Power Switch
STOP
FEED
PAUSE
After "Sensor Cal Mode" lights up, release the keys to change
21
the printer to sensor adjustment setting mode1
POWER
ERROR
Sensor Cal Mode
See Through
Quick Sensor Selection Method
(Transparent
Reflective)
To switch from transparent to reflective sensor, hold down the MENU key
and then press the STOP key. Each time you press the STOP key, you switch
to back and forth between the two sensor types.
If the transparent sensor is selected, "See Through" is displayed and the
buzzer sounds once. If the reflective sensor is selected, "Reflect" is displayed
and the buzzer sounds twice.
POWER
ERROR
Sensor Cal Mode
Reflect
STOP
MENU
Press/Release
Hold