Cisco Wide Area Application Engine 7341, 7371, and 674 Hardware Installation Guide
OL-15012-02
Chapter 6 Troubleshooting the System Hardware
Symptoms and Solutions
Diagnostic Error Codes
In the following error codes, if
XXX
is 000, 195, or 197,
do not
replace a
component. The descriptions for these error codes are as follows:
•
000—The test passed.
•
195—The Esc key was pressed to stop the test.
•
197—Warning; a hardware failure might not have occurred.
BRD
An error has occurred on the
system board.
1.
Check the LEDs on the system board to
identify the component that is causing the
error.
2.
Check the system error log. (See the
“Viewing Error Logs” section on
page 6-10
.)
PCI
An error has occurred on a PCI
bus or on the system board. An
additional LED will be lit next to
a failing PCI slot.
1.
Check the LEDs on the PCI slots to
identify the component that is causing the
error.
2.
Check the system error log. (See the
“Viewing Error Logs” section on
page 6-10
.)
3.
If you cannot isolate the failing adapter
through the LEDs and the information in
the system error log, remove one adapter at
a time from the failing PCI bus, and restart
the device after each adapter is removed.
4.
Check the PCI riser card.
5.
Check the system board.
Table 6-8
Diagnostic-Panel LED Error Definitions (continued)
Diagnostic-Panel
LED
Description
Cause and Action