Chapter 6 Troubleshooting the System Hardware
Symptoms and Solutions
6-28
Cisco Wide Area Application Engine 7341, 7371, and 674 Hardware Installation Guide
OL-15012-02
4-4-4
Optional system management
adapter not installed or not
functioning correctly.
Pertains to a nonavailable hardware option. Not
applicable to the device.
Two short
beeps
Information only, the configuration
has changed.
1.
Run diagnostics.
2.
Run the configuration/setup utility
program.
Three short
beeps
Possible memory problem.
1.
Check the DIMM.
2.
Check the system board.
One
continuous
beep
Possible microprocessor problem.
1.
Check the microprocessor.
2.
Check the optional microprocessor (if
installed).
3.
Check the system board.
Repeating
short beeps
Possible keyboard problem.
This error pertains to keyboards, which are not
supported in the WAAS software.
One long and
one short beep
Possible video controller problem.
1.
Check the video adapter.
2.
Check the system board.
One long and
two short beeps
Possible video controller problem.
1.
Check the video adapter.
2.
Check the system board.
One long and
three short
beeps
Problem with the monitor or video
controller.
1.
Check the monitor and monitor cable.
2.
Check the system board.
Two long and
two short beeps
Problem with the optional video
adapter.
Not applicable to the device.
1.
CMOS = Complementary Metal Oxide Semiconductor
2.
DMA = Direct Memory Access
3.
WAAS software does not support keyboards. No keyboard errors are expected; however, if a keyboard error appears during
bootup, contact your customer service representative.
Table 6-6
Beep Symptoms (continued)
Beep Symptom
Error
Cause and Action