S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
1-3
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring Smart Call Home
Information About Call Home
destination profile only if that Call Home alert belongs to one of the alert groups associated with that
destination profile and if the alert has a Call Home message severity at or above the message severity set
in the destination profile (see the
“Call Home Message Levels” section on page 1-5
lists supported alert groups and the default CLI command output included in Call Home
messages generated for the alert group.
Table 1-1
Alert Groups and Executed Commands
Alert Group
Description
Executed Commands
Cisco-TAC
All critical alerts from the other alert groups
destined for Smart Call Home.
Execute commands based on the
alert group that originates the alert.
Configuration
Periodic events related to configuration.
show module
show module fex
show running-config all
show startup-config
show version
Diagnostic
Events generated by diagnostics.
show diagnostic result fex all
show diagnostic result module all
show diagnostic result module
number
show logging last
number
show module
show module fex
show prom all
show tech-support platform
show tech-support platform
callhome
show tech-support platform
callhome fex
show version
EEM
Events generated by EEM.
show diagnostic result module all
show diagnostic result module
number
show module
show tech-support platform
Environmental
Events related to power, fan, and
environment-sensing elements such as
temperature alarms.
show environment
show environment fan
show environment fex all
show environment power
show environment temperature
show logging last 1000
show module
show tech-support platform
callhome
show version