Error Message
SYSTEMHEALTH-4-OHMS_FREE_DISK_FAILING: Free Disk Space on partition
[chars] is starting to go below threshold for module [dec]
Explanation
The system Health Free Disk Space has gone below the threshold.
Recommended Action
Force a switchover if a standby supervisor is available, or reboot the switch to
recover.
Error Message
SYSTEMHEALTH-4-OHMS_INBAND_FAILING1: Inband test failed [dec] times
for module [dec].
Explanation
Inband Failing.
Recommended Action
No action is required.
Error Message
SYSTEMHEALTH-4-OHMS_INBAND_TEST_ERRORS: Too many errors while running
the inband test.
Explanation
Inband test has had too many errors while running.
Recommended Action
No action is required.
Error Message
SYSTEMHEALTH-4-OHMS_LC_DAEMON_EXITED: System Health process running
on module [dec] exited due to internal errors. Will attempt to restart.
Explanation
The system Heath line card daemon exited.
Recommended Action
No action is required.
Error Message
SYSTEMHEALTH-4-OHMS_LC_DAEMON_FAILED: System Health process running
on module [dec] failed due to fatal errors.
Explanation
The system Heath line card daemon failed.
Recommended Action
No action is required.
Error Message
SYSTEMHEALTH-4-OHMS_LC_DAEMON_RESTARTED: System Health process
running on module [dec] restarted.
Explanation
The system Heath line card daemon restarted.
Recommended Action
No action is required.
Error Message
SYSTEMHEALTH-4-OHMS_MOD_SNAKE_PATH_FAILURE: Snake Loopback data path
failure on module [dec].
Explanation
Snake data path only error.
Recommended Action