![Cisco AP775A - Nexus Converged Network Switch 5010 Reference Download Page 161](http://html.mh-extra.com/html/cisco/ap775a-nexus-converged-network-switch-5010/ap775a-nexus-converged-network-switch-5010_reference_67336161.webp)
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-123
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
DIAGMGR Messages
DIAGMGR-3
Error Message
DIAGMGR-3-DIAG_MAJOR_DEFECT: Module <[dec]> Test <[chars]> detected
a Major Error Please use 'show diagnostic result <target>' to see test results
Explanation
A major error was detected during diagnostic testing.
Recommended Action
Re-seat the card and retry the test. If the same result occurs after reseating the
card and retrying the test, copy the error message exactly as it appears on the screen and gather the
output of show tech-support and any other relevant information. Contact your technical support
representative with the gathered information.
Error Message
DIAGMGR-3-DIAG_MINOR_DEFECT: Module <[dec]> Test <[chars]> detected
a Minor Error Please use 'show diagnostic result <target>' to see test results
Explanation
A mior error was detected during diagnostic testing.
Recommended Action
Re-seat the card and retry the test. If the same result occurs after reseating the
card and retrying the test, copy the error message exactly as it appears on the screen and gather the
output of show tech-support and any other relevant information. Contact your technical support
representative with the gathered information.
Error Message
DIAGMGR-3-GET_CURR_SLOT_FAIL: Failed to get the current slot for the
process. Error:[chars]
Explanation
The process initialization has failed to get the current slot.
Recommended Action
This is an informational message stating that a process initialization failure.
DIAGMGR-4
Error Message
DIAGMGR-4-CURR_SLOT_OFFLINE: Recevied an LC offline event for the
current slot:[dec]. Ignoring it
Explanation
The process received an offline event for the slot it is running. Ignoring it.
Recommended Action
This is an informational message stating that an unexpected event has been
encountered.
Error Message
DIAGMGR-4-DISRPT_TST_START: Starting Test <[chars]> on Module <[dec]>
is Disruptive
Explanation
Starting a Disruptive Test can disturb the system's normal functionality.
Recommended Action
Reset target module.