Configuring
Cards
Processor
Card Contigtratou
Regster
For
both the
CSC/3
and
CSC/4
processor
cards
the 50-pin header
in the
center of
the
front
edge
of
the
card
is
used
as
configuration
register
for
processor
functions
and
diagnostics
The
following
section describes the
settings
for
this
register Figure 5-2
shows
partial
component-side
view
of
the
processor
cards
Both
cards
contain
the
same components
and
basic physical layout
as
illustrated
gurationOonsole
register
connector
Figure
5-2
CSC/3
aiid
CSC/4 Processor
CardsPartial
Component-Side
View
Configuration
Register
Settings
The
processor
cards have
16-bit
hardware
configuration
register the
far right
16
pairs
of
jumper
pins
on
the
50-pin header
in
the center of the
card Refer
to
Figure
5-3
Bit
or
position
is
the
far right vertical
pair of
pins To
set
bit to
insert
vertical
jumper To
clear
bit to
remove
the
vertical
jumper
Figure 5-3
shows
the configuration
register
with the factory
settings
for
the
CSC/3
and
CSC/4
15
14
13
12
1110
Positions
bits
Note
Positions
and
shown
as
factory defaults
Pattern
0-0-0-1
ROM-boot
jumper
Pattern
0-0-1-0
ROM-monitor
and
configuration
file
boot
jumper
Figure
5-3
CSC/3 and CSC/4
Configuration
Register
To change
configuration
register
settings
turn
off
the
system
set
or
clear
the
bits
by
inserting or
removing jumpers and
restart
the system
or
change
the
jumper
settings
while
the
power
is
still
on
and then give the privileged
command
reload
It
is
not necessary
to
remove
the
processor
card
from
the
backplane
or
to
turn off the
power
to
change
jumper
setting
Note
Configuration
register
setting
changes
take
effect
only
after
the
system
restarts
5-4
AGS
Hardware
Installation
and Maintenance
Summary of Contents for AGS+
Page 1: ...CISCO SYSTEMS ...
Page 11: ...AGS Hardware Installation and Maintenance ...
Page 17: ...Document Conventions xvi AGS Hardware Installation and Maintenance ...
Page 27: ...Chassis Power Budget 1 10 AGS Hardware Installation and Maintenance ...
Page 39: ...Chassis Components 2 12 AGS Hardware Installation and Maintenance ...
Page 57: ...System Bootstrap Diagnostics 4 10 AGS Hardware Installation and Maintenance ...
Page 83: ...Card Illustrations 5 26 AGS Hardware Installation and Maintenance ...
Page 105: ...FOOl Optical Bypass Switch Pinout A 22 AGS Hardware Installation and Maintenance ...
Page 121: ...Applique LED Indicators B lB AGS Hardware Installation and Maintenance ...
Page 125: ...C 4 ACS Hardware Installation and Maintenance ...
Page 127: ...Compliance Provisions D 2 AGS Hardware Installation and Maintenance ...
Page 129: ...E 2 AGS Hardware Installation and Maintenance ...