General
Site
Requirements
Site
Envkonment
The
chassis can be used
as
tabletop or
rack-mounted
system
in
data processing
or lab
environment Because
the large cooling fan in
the
chassis
is
somewhat
noisy
approximately
60
decibels
weighted
the chassis
is
intended
for unattended
or
computer
room
use
Table 2-1
lists
the
air
temperature
and
voltage
warning
thresholds
for
the chassis
and
Table 2-2
lists
the environmental
specifications
Depending upon
the temperature
and
cooling
capability of your
site
the chassis
will
require
at least
minimum
amount
of clearance
approximately
to
inches
in an enclosed
rack
or closet
on
all
sides
to
prevent
the chassis
from
taking
in
the heated
exhaust
air
of other
equipment
Table
2-1
Chassis
Air
Temperature
and
Voltage
Warning
and
Fatal
Thresholds
Designation
Warning
Threshold
Fatal
Threshold
Internal
intake
air
at
the sensor
tolerance
is
3C
104F
40C
1094F
43C
Air
flow
exhaust
Warning
Message
13
64F
58C
5V
supply
5%
10%
12V
supply
10%
15%
12V
supply
10%
15%
SVsupply
5%
10%
Table
2-2
Chassis Environmental
Specifications
Description
Minimum
Maximum
Ambient
temperature
operating
32F
0C
104F
40C
Ambient
temperature
nonoperating
40F
40C
185F
85C
Ambient
humidity
operating
5%
RH
95%
RH
Ambient
humidity
nonoperating
5%
RH
95%
RH
Altitude
operating
500 152
10000
3050
Altitude nonoperating
1000
304
30000
9144
Vibration
operating
5500
Hz
0.5G
0.1
oct/mm
Vibration nonoperating
5100
Hz
1G
0.1
oct/mm
100500
Hz
1.5G0.2oct./min
5001000 Hz
1.5G 0.2
oct/mm
All values of
relative
humidity
RH
are
noncondensing
2-4
AGS
Hardware
Installation
and Maintenance
Summary of Contents for AGS+
Page 1: ...CISCO SYSTEMS ...
Page 11: ...AGS Hardware Installation and Maintenance ...
Page 17: ...Document Conventions xvi AGS Hardware Installation and Maintenance ...
Page 27: ...Chassis Power Budget 1 10 AGS Hardware Installation and Maintenance ...
Page 39: ...Chassis Components 2 12 AGS Hardware Installation and Maintenance ...
Page 57: ...System Bootstrap Diagnostics 4 10 AGS Hardware Installation and Maintenance ...
Page 83: ...Card Illustrations 5 26 AGS Hardware Installation and Maintenance ...
Page 105: ...FOOl Optical Bypass Switch Pinout A 22 AGS Hardware Installation and Maintenance ...
Page 121: ...Applique LED Indicators B lB AGS Hardware Installation and Maintenance ...
Page 125: ...C 4 ACS Hardware Installation and Maintenance ...
Page 127: ...Compliance Provisions D 2 AGS Hardware Installation and Maintenance ...
Page 129: ...E 2 AGS Hardware Installation and Maintenance ...