Environmental
Reporting
Features
TroubUeshooting
the
System
Cards
and
Cabes
Check
the
following
items
to
help
isolate
the
problem
System
will
not boot
properly
or constantly/intermittently reboots
Check
the processor
card connection
to
the backplane
and
the console
cable
Check
the
LED
indicators
See
Appendix
Suspect
the processor
card or software
System
boots
with
particular
card disconnected
from
the
backplane
suspect
the
card
System
boots
with
particular
applique
or
cable disconnected
suspect
the applique
or
cable
System
will
not boot
from
Flash
memory
assuming
software
is
preconfigured
to
do
so
Check
the connection
between
the
Flash card
and
the
MCI
CSC-1R CSC-2R
or
CSC-ENVM
card
Check
the configuration
register
on the processor
card
for
the correct
jumper
setting
for
booting
from Flash Refer
to
the section
Configuration
Register Settings
in Chapter
System boots
but console
screen
is
frozen
Check
the external
and
internal
console
connections
Verify
the
console
baud
rate
in the
terminals
documentation
Card
is
not recognized
by
the
system
Check
the card connection
to
the
backplane
Check
the
LEDs
on
the card
and
applique
See
Appendix
Check
the card-numbering
switch
See
Chapter
Card
is
recognized
but interface
ports
will
not
initialize
Check
the
internal
interface
cables
for
connection
Check
the external interface cables
for connection
Check
DCE/DTE
jumpers
See
Chapter
Check
that
the
interface
is
not administratively shut
down
limesaver
In general
if
particular
port
will
not
initialize
and
the
LED
indicator
on
the
interface
card
is
lit
the
problem
may
be
the applique or
internal
cabling
however
to
save
time during the
troubleshooting
process check
the
more
accessible
interface
card before checking
the applique
Environmenta Reportng
Features
The
CSC-ENVM
card
BNVM
not only provides nonvolatile
and Multibus
memory
but
it
also
provides
the environmental
monitoring
required for
the
chassis This card checks
input
and
exhaust
air
temperatures
and
backplane-voltage
levels
If
the ambient
temperature
exceeds
given
range
and
threshold
or
if
intake airflow
is
restricted or
if
any
of the voltages
drift
away from
the factory
settings
an
error
is
detected
and
the
ENYM
shuts
down
all
functions
in
the chassis
The
blower
will
continue
to
run
Power
is
returned
by
turning
off
the
main
breaker
switch
waiting
20
to
30
seconds and
then turning
on
the
main
breaker
switch
This
is
called toggling
the
breaker
switch
Troubleshooting
the
Initial
Hardware
Configuration
4-3
Summary of Contents for AGS+
Page 1: ...CISCO SYSTEMS ...
Page 11: ...AGS Hardware Installation and Maintenance ...
Page 17: ...Document Conventions xvi AGS Hardware Installation and Maintenance ...
Page 27: ...Chassis Power Budget 1 10 AGS Hardware Installation and Maintenance ...
Page 39: ...Chassis Components 2 12 AGS Hardware Installation and Maintenance ...
Page 57: ...System Bootstrap Diagnostics 4 10 AGS Hardware Installation and Maintenance ...
Page 83: ...Card Illustrations 5 26 AGS Hardware Installation and Maintenance ...
Page 105: ...FOOl Optical Bypass Switch Pinout A 22 AGS Hardware Installation and Maintenance ...
Page 121: ...Applique LED Indicators B lB AGS Hardware Installation and Maintenance ...
Page 125: ...C 4 ACS Hardware Installation and Maintenance ...
Page 127: ...Compliance Provisions D 2 AGS Hardware Installation and Maintenance ...
Page 129: ...E 2 AGS Hardware Installation and Maintenance ...