Appendix C EZ-DSL Microfilter Specifications
Specifications
C-4
Cisco 600 Series Installation and Operation Guide
78-11190-01
Dimensions
•
4.50 x 2.75 inches
•
11.4 x 6.98 cm
Figure C-2
Wall Mount Microfilter
Installation Instructions
Step 1
Remove any existing wall mounts.
Step 2
Remove 3 inches from the outer jacket of telephone wire in the outlet box. Strip
.75 inch from each individual conductor.
Step 3
Loosen screws on all jack terminals. Each terminal is color coded. Connect four
wires to corresponding terminal screws. Check wiring.
Table C-2
Wall Mount Microfilter Pinouts
Pin
Signal
3
Ring
4
Tip