WIMIC Troubleshooting
Error and Event Messages
11
Cisco 3200 Series Wireless MIC Software Configuration Guide
DOT11-6-ROGUE_AP: Rogue AP
[mac-address] reported. Reason: [chars]
A station has reported a potential rogue
bridge for the stated reason.
None.
SCHED-3-UNEXPECTEDMESSAGE:
Unknown message [hex] received (ptr
arg [hex], num arg [hex]).
A process can register to be notified when
various events occur in the router. This
message indicates that a process received
a message from another process that it
does not know how to handle.
Copy the error message exactly as it
appears, and report it to your technical
support representative.
SCHED-3-UNEXPECTEDEVENT:
Process received unknown event (maj
[hex], min [hex]).
A process can register to be notified when
various events occur in the router. This
message indicates that a process received
an event that it did not know how to
handle.
Copy the error message exactly as it
appears, and report it to your technical
support representative.
Miscellaneous Messages
WGB_CLIENT_VLAN: Workgroup
Bridge Ethernet client VLAN not
configured.
A VLAN configuration is missing for
client devices connected to a workgroup
bridge.
Use the workgroup-bridge client-vlan
command to assign a VLAN to
Ethernet client devices connected to the
workgroup bridge.
UNDER_VOLTAGE: Under voltage
condition detected.
The hardware under voltage detection
logic has reported a low voltage
condition.
Check the power supply and associated
power connections.
Table 2
Error and Event Messages (continued)
Message
Explanation
Recommended Action