VCC-5CXP3NIR
Rev. 905-0123-00
©2018 CIS Corporation. All rights reserved.
8
7.3
Camera Sync. Mode
・
TriggerSelectorAndActivation
AquisitionMode
:
Internal sync. mode (Free run mode)
FrameStartRisingEdge
:
External trigger sync. mode (Fixed trigger shutter mode: rising edge)
FrameStartFallingEdge
:
External trigger sync. mode (Fixed trigger shutter mode: falling edge)
FrameStartLevelHigh
:
External trigger sync. mode (Pulse width trigger shutter mode
:
High active)
FrameStartLevelLow
:
External trigger sync. mode (Pulse width trigger shutter mode
:
Low active)
FrameBurstStart
:
Internal sync. mode (Burst mode of Sequence function)
・
TriggerSource
This is to set how to input the trigger at external trigger sync. mode.
LinkTrigger0
:
Using LOW SPEED uplink of CoaXPress, input triggers from a frame grabber board via coaxial cable.
LineIn
:
Input triggers via No. 5 pin of the circular connector on the camera rear.
・
TriggerSoftware
When this command is executed, a trigger is generated in the camera and images for 1 frame are captured.
Please be noted that time accuracy with this trigger is not so precise as the trigger generated by
TriggerSource explained the above. Only TriggerSelectorAndActivation
--- FrameStartRisingEdge mode can be used
as Acquisition Control mode.
7.3.1
Internal Sync. Mode (Free Run Mode)
This is a mode to use triggers continuously made in the camera. No external trigger shall be used.
Configuration
Frame rate
(fps)
8bit
10bit
CXP-1
21.3
16.3
CXP-2
42.6
34.8
CXP-3
42.6
42.6
CXP-5
85.1
69.5
CXP-6
85.1
85.1
Acquisition Control
TriggerSelectorAndActivation
AquisitionMode
FrameStartRisingEdge
FrameStartFallingEdge
FrameStartLevelHigh
FrameStartLevelLow
FrameBurstStart
TriggerSource
LinkTrigger0
Line0
TriggerSoftware
(Execute)