Basic Operation for Sequence Control   

 
Please follow the step by step instructions below to use sequence control function.

 

       

 

 

AquisitionControl --- TriggerSelectorAndActivation Setting 

This is to set camera operational mode.   

 

 

  Sub-sampling, ROI settings 

Please turn OFF SubsamplingMode.    Please set ROI of ImageFormatControl to ROIQuickChangeOff.     

This does not work with sequence control function.   

 

 

  Set the parameter table (SequencerParameterSetSelector) for sequence 

Please set ExposureTime and Gain of each parameter set. 

 

 

  Set the parameter set to be used for sequence

ParameterIndexNumber), index loop count       

(IndexLoopCount), entire sequence loop count (SeqencerLoopCount), and the range of index to be used.

 

(ActiveIndexNumber) 
 

 

 

SequencerControl --- SequencerActivation   

This is to set the start operation of sequence mode.    By setting any preferred [SequencerActivation] from Off, the 
camera will become stand-by status for a trigger. 

 

 

  Input a trigger pulse to start sequence control function. 

 
      

  [Notes] 

 

Please determine link configuration beforehand to set each setting.   
 

 

Trigger input timing restrictions at sequence control is the same as the one for normal mode. 

 

 

Please turn OFF SequencerActivation once to set the settings for sequence.   

 

 

UserSetSave and UserSetDefault are not executed at SequencerMode.  Please set them after power up the camera. 
(UserSetSave and UserSetDefault can be executed for other sequence settings).   

 

 

If a trigger had been input to the camera in advance, sequence would start when the SequencerActivation is set to 
other than OFF.    Please do not input any triggers to switch SequencerActivation. 

 

 

Please refer to the maximum exposure time specified in the Section 8.2, Exposure Time Settings, for exposure time 
to input to each parameter settings.   

 

 

At burst mode, the screen will hold the last picture of sequence control when sequence control is completed. 

 

 

 

Please turn OFF SequencerActivation to return to the condition before sequence control was performed. 

 

 

 

 

 

Summary of Contents for VCC-5CXP3NIR

Page 1: ...VCC 5CXP3NIR Rev 905 0123 00 2018 CIS Corporation All rights reserved 1 CoaXPress I F 5 3M CMOS Near Infrared Camera VCC 5CXP3NIR Product Specifications Operational Manual CIS Corporation English...

Page 2: ...ee Run Mode 8 7 3 2 External Trigger Sync Mode 9 8 Camera Function Settings 12 8 1 Gain Settings 12 8 2 Exposure Time Settings 13 8 3 ROI Region of Interest 14 8 4 Sub sampling 16 8 5 Image Sensor Def...

Page 3: ...nnecting the camera module Improper connection may cause damages not only to the camera module but also to the connected devices Confirm the mutual ground potential carefully and then connect the came...

Page 4: ...Free run mode Camera internal trigger Trigger mode Preset shutter trigger Pulse width shutter trigger 15 Partial Scan ROI 8 Preset patterns Including full resolution ROI OFF 16 Power Requirements PoCX...

Page 5: ...evel CXP 1 01 1 2 CXP 2 6 01 01 At 8bit Gain 0dB With gain up set up level changes as well It is adjustable with black level adjustment Black Offset 5 External Trigger Signal Input CoaXPress BNC Conne...

Page 6: ...TRIGGER_IN Trigger input 6 GND Conduction with camera casing NC means Non Connection Do not connect anything to the terminal 3pins SIGNAL_OUT Circuit The camera internal timing signals can be output P...

Page 7: ...erSetDefault is executed settings shall be restored to the initial settings This can be done only when its link configuration CxpLinkConfiguration is CXP 1 Unless otherwise UserSetSave is executed the...

Page 8: ...a frame grabber board via coaxial cable LineIn Input triggers via No 5 pin of the circular connector on the camera rear TriggerSoftware When this command is executed a trigger is generated in the cam...

Page 9: ...e while reading out signals for the prior frame No video would be output in case of when a trigger was re input at the restricted timing explained the above or at the timing to end exposure right afte...

Page 10: ...xposure time Values shall not be changed randomly under fixed condition Fixed Trigger Shutter Mode This is a mode to start exposure by inputting trigger signals and to set its exposure time manually o...

Page 11: ...gger cycle needs to be longer than FVAL period 1 framerate Trigger operation is CLK sync H V sync reset The minimum trigger width is 30 s Functionally there is no upper limitation for pulse width Howe...

Page 12: ...ever please be noted that the image quality will be reduced when gain setting is increased We recommend you to evaluate it first AnalogControl PresetGainX Gain_x1 Gain_x1_5 Gain_x2 Gain_x3 Gain_x4 Gai...

Page 13: ...us Shutter_1_5000 1 5000 200 us Shutter_1_10000 1 10000 100 us ExposureTime Manual shutter mode The maximum exposure time is limited according to the video output format link rate and ROI settings Ple...

Page 14: ...2M 8bit 21 3 42 6 42 6 85 1 85 1 10bi 16 3 34 8 42 6 69 5 85 1 Pattern1 2048x2048 2K2K 4M 8bit 21 5 51 0 51 0 101 4 101 4 10bi 19 2 43 5 51 0 85 8 101 4 Pattern2 1920x1200 WUXGA 8bit 41 7 90 1 90 1 1...

Page 15: ...VCC 5CXP3NIR Rev 905 0123 00 2018 CIS Corporation All rights reserved 15 ROI area are cut out with the image sensor centered...

Page 16: ...Execute re grabbing the viewer to acquire images The frame rates when sub sampling is in operation at free run mode are as follows 8 5 Image Sensor Defective Pixel Correction CIS compensates the notic...

Page 17: ...te properly without video output when trigger mode is in operation To execute DetectShading please input a trigger within 200ms after executed DetectShading Shading correction ShadingCorrection Turn S...

Page 18: ...for the lighting pattern at Active setting Lighting status Camera Status OFF PoCXP No supply Green Slow blinking 0 5Hz Connection completed between device and host Green ON Transmitting video data Or...

Page 19: ...FrameActive This is to indicate the frame effective period with Hi Active LineActive This is to indicate the line effective period with Hi Active TriggerPacketActive This is to decode and output the u...

Page 20: ...meter set number to be applied for the maximum of sixteen indexes There are three control modes Trigger mode Burst mode and Index mode Please refer to the chart below for the settable AquisitionMode C...

Page 21: ...Activation from Off the camera will become stand by status for a trigger Input a trigger pulse to start sequence control function Notes Please determine link configuration beforehand to set each setti...

Page 22: ...by a camera internal trigger and the specified parameter set is applies to the camera Shutter Gain Param 0 Shutter Gain Param 1 Shutter Gain Param 2 Shutter Gain Param 3 Shutter Gain Param 4 Shutter G...

Page 23: ...ence starts with a trigger input when TriggerSelectorAndActivation is set to FrameStartRisingEdge or FrameStartFallingEdge Exposure time for each frame and shall be controlled by the preset sequence p...

Page 24: ...the image output for the sequence loop count is completed sequence operation ends 2 High level control TRIG IN Video Out Effective Line Exposure Effective Line FVAL Out Sequence Control Start Sequence...

Page 25: ...e controlled by the preset parameter set 2 Pulse width control Exposure time for each frame is the pulse width of the trigger Exposure time of the parameter set is not referred Notes for the issuing t...

Page 26: ...nce control to the low level control of the trigger pulse FrameBurstStart Set when sequence control is used at burst mode Settings for how to change to sequence mode SequencerControl SequencerActivati...

Page 27: ...re saved even when the parameter number is changed SequencerParameterSetSelector 0 15 Parameter set SetConfiguration SequencerExposureTime Exposure time SequencerExposureTimeMAX Indicates the maximum...

Page 28: ...mber RepeatNumberStatus Indicate the repeating count of executing Index number LoopNumberStatus Indicate the loop count of executing sequence If the loop count is set to infinite count up to 1023 coun...

Page 29: ...kTrigger0 ExposureTime 3333 0 AnalogControl blackOffset 64 Gain 1 0 ShadingCorrection False DefectivePixelCorrection True DigitalIOControl LineSource OFF SequencerControl SequencerActivation Off Seque...

Page 30: ...VCC 5CXP3NIR Rev 905 0123 00 2018 CIS Corporation All rights reserved 30 11 Dimensions 11 1 Optical Axis Accuracy...

Page 31: ...VCC 5CXP3NIR Rev 905 0123 00 2018 CIS Corporation All rights reserved 31 11 2 Camera Dimensions...

Page 32: ...of God In case damages or losses are caused by deliberate or accidental misuse by the user or failure to observe the information contained in the instructions in this Product Specification and Operati...

Reviews: