9.6 Settings for Sequence Control
Execute UserSetSave to save the settings. Please be noted that SequencerActivation is not saved so that after power is
turned on, it always becomes OFF. When using sequence mode, set SequenceActivation every time.
◇
Settings for how to control sequence function
Acquisition Control
TriggerSelectorAndActivation
AquisitionMode
FrameStartRisingEdge
FrameStartFallingEdge
FrameStartLevelHigh
FrameStartLevelLow
FrameBurstStart
・
FrameStartRisingEdge
:
Set sequence control to the rising edge control of the trigger pulse.
・
FrameStartFallingEdge
:
Set sequence control to the falling edge control of the trigger pulse.
・
FrameStartLevelHigh
:
Set sequence control to the high level control of the trigger pulse.
・
FrameStartLevelLow
:
Set sequence control to the low level control of the trigger pulse.
・
FrameBurstStart
:
Set when sequence control is used at burst mode.
◇
Settings for how to change to sequence mode
SequencerControl
SequencerActivation
Off
FrameStartPredefined
FrameStartIndexSelector
FrameBurstStartEdge
FrameBurstStartLevel
FrameBurstStartSoftware
・
FrameStartPredefined
:
Set to start trigger mode or burst mode.
・
FrameStartIndexSelector
:
Set to start index mode.
・
FrameBurstStartEdge
:
Set to start burst mode edge control.
・
FrameBurstStartLevel
:
Set to start burst mode High level control.
・
FrameBurstStartSoftware
:
Set to start burst mode register start.
◇
Settings for sequence count and its range
SequencerConfigurationParameter
Setting range
SequencerLoopCount
Entire sequence loop count
1-1023
0: infinite
ActiveIndexNumber
The Index range to execute
0-15
IndexSelectorModeIndexNumber
Index number to be used at index mode
0-15
ParameterIndexNumber
Index 0-15
Parameter number for Index 0-15
0-15
IndexLoopCount
IndexCount 0-15
Each loop count for Index 0-15
0-1023