VCC-5CXP3NIR
Rev. 905-0123-00
©2018 CIS Corporation. All rights reserved.
22
9.2
Trigger Mode and Burst Mode Operational Outline
This is a mode to specify Index transition flow in advance.
The repeating count for each Index, the number of the Index to be used, and the loop count can be set.
・
Trigger mode
Index repeat count is added up every time external trigger is input, and the specified parameter set is applied to the
camera.
・
Burst mode
It operates as the same way as internal sync mode free run. Sequence starts by a trigger, Index repeat count
increments automatically by a camera internal trigger, and the specified parameter set is applies to the camera.
Shutter
Gain
Param
#0
Shutter
Gain
Param
#1
Shutter
Gain
Param
#
2
Shutter
Gain
Param
#3
Shutter
Gain
Param
#4
Shutter
Gain
Param
#8
Applying param
Index
0
Applying param
Index
1
Applying param
Index2
Applying param
Index
3
Applying param
Index
#4
Applying param
Index
#5
Param
#0
Param
#1
Param
#0
Param
#1
Param
#4
Param
#8
200
32
100
32
60
3
1023
1
IndexLoopCount
各Indexを繰り返す回数
SequencerLoopCount
0
: 無限loop,
1
~: 有限loop数
ActiveIndexNumber
実行するIndexの範囲
ParameterIndexNumber
各Indexとパラメータセットの紐付け
SequencerParameterSetSelector
Index Loop Count
Repeating count for each index
Sequencer Loop Count
0: Infinite loop
1~: Limited loop
Active Index Number
Index range to execute
Parameter Index Number
Combination of each Index and parameter set