VCC-5CXP3NIR
Rev. 905-0123-00
©2018 CIS Corporation. All rights reserved.
7
□
5pins TRIGGER_IN Circuit
Trigger signals can be input from an external equipment directly into the camera. When you use this terminal, set
TriggerSource of Acquisition Control to Line IN. For the details, please refer to the Section 7.
・
5.0V, 3.3V CMOS level input (TTL compatible)
・
Input voltage Low: 0.5Vdc (Min), High: 2.1Vdc (Max)
6.
How to Save and Initialize the Settings
UserSets
UserSetSave
(Execute)
UserSetDefault
(Execute)
When UserSetDefault is executed, settings shall be restored to the initial settings. This can be done only when its link
configuration (CxpLinkConfiguration) is CXP-1. Unless otherwise UserSetSave is executed, the settings would not be saved.
If you wish to save the setting values, execute UserSetSave. Doing so, the setting values are saved in the camera internal
ROM. And, the saved settings are reflected when the camera is turned on next time.
7.
Camera Operational Mode
7.1
Link Configuration
Transfer Control
CxpLinkConfiguration
CXP1_X1
CXP2_X1
CXP3_X1
CXP5_X1
CXP6_X1
7.2
Pixel Format Settings
ImageFormatControl
PixelFormat
Mono8
Mono10
HD74LV1GT14ACME
1
2
3
5
4
100
1K
+5.0V
(CAMERA_INTERNAL)
TRRIGER_IN