1 — I N P U T P O W E R S U P P LY
The input power supply line for the Charge Point must be hardwired from a dedicated
power transformer or generator and not by LV overhead power lines. It has to done
under electrical safety regulations according to your country.
Additionally, only for
Raption 100
case, installation must be physically separated from
residential environments by distance greater than 30m or by a structure which acts
as a barrier to radiated phenomena.
2 — P O W E R S U P P LY L I N E D I M E N S I O N I N G
The dimensioning of the input power supply line of the Charge point must be checked
by a qualified electrician. Note that various factors, such as, cable length between
distribution board and Charge point, maximum input current of the Charge point; the
installation way may have influence of the selected cable. The installation company
will be responsible for dimensioning the wires cross section and the electrical
protections, taking into account the conditions above.
3 — M A X I M U M C U R R E N T O U T P U T
Depending on the input power line, you can carry out the charging sessions to the
electric vehicle with different power output level, it is possible to limit the maximum
output power by software limitation so as not to exceed the available input power.
In order to implement this limitation by software, please, refer to the
INSTRUCTION
MANUAL (M186B01-03-xxx).
Note:
In the Chapter 4, subsection E, you are going to find more electrical instructions
so as to implement a secure POWER SUPPLY LINE.
Take into consideration this section before start wir-
ing connections of the charge point.
Before the installation
B
Electrical wiring considerations
9
Installation Guide
Raption
Summary of Contents for Raption 100
Page 1: ...Raption Series INSTALLATION GUIDE M186A01 03 21D...
Page 2: ...2 Raption Installation Guide...
Page 15: ...15 Installation Guide Raption...
Page 16: ...3 A Dimensions Units specified in millimeters 16 Raption Installation Guide...
Page 56: ...56 Raption Installation Guide...
Page 58: ...58 Raption Installation Guide...
Page 59: ...59 Installation Guide Raption...