MODELS SPECIFICATIONS
(Continuation) Raption 50 - 400V Models
MODELS
CCS1-CHA T1C32
CCS2-CHA T2C32
CCS1-CHA T2S32
CCS2-CHA T2S32
CCS2-CHA T2C63
Maximum AC input
current
108 A
108 A
138 A
Required power supply
capacity
75 kVA
75 kVA
96 kVA
Maximum output
power
CCS1-CHA T1C32
DC:
50 kW (@400Vdc)
AC:
22 kW
DC:
50 kW(@400Vdc)
AC:
43 kW
DC:
50 kW(@400Vdc)
AC:
7.4 kW
CCS2-CHA T2C32
DC:
50 kW(@400Vdc)
AC:
22 kW
Output voltage range
CCS1-CHA T1C32
DC:
50 - 500 Vdc
AC:
400 V
~
DC:
50 - 500 Vdc
AC:
400 V
~
DC:
50 - 500 Vdc
AC:
230 V
~
CCS2-CHA T2C32
DC:
50 - 500 Vdc
AC:
400 V
~
Maximum output
current
DC:
125 A
AC:
32 A
DC:
125 A
AC:
32 A
DC:
125 A
AC:
63 A
Number of connectors
3
3
3
Connector type
CCS1-CHA T1C32
CCS1-CHA T2S32
CCS2-CHA T2C63
K
M
M
M
B
C
C
CCS2-CHA T2C32
CCS2-CHA T2S32
K
K
M
M
C
C
46
Raption
Installation Guide
Summary of Contents for Raption 100
Page 1: ...Raption Series INSTALLATION GUIDE M186A01 03 21D...
Page 2: ...2 Raption Installation Guide...
Page 15: ...15 Installation Guide Raption...
Page 16: ...3 A Dimensions Units specified in millimeters 16 Raption Installation Guide...
Page 56: ...56 Raption Installation Guide...
Page 58: ...58 Raption Installation Guide...
Page 59: ...59 Installation Guide Raption...