AFQm
The phase balancing option in
AFQm-3WF-xxxx
works in unbalances produced by loads
connected between phases in three-phase mains without neutral. The
AFQm-3WF-xxxx
does not compensate unbalances produced by single-phase loads connected between
phase and neutral. Use a
AFQm-4WF-xxxx
to correct this type of unbalances.
Priority
Enable this option so that the device prioritises the functions in case of filter current saturation due to
overload:
With the function
enabled
, the current balancing between phases and the reactive current compensa-
tion is prioritised over the harmonic filtering.
With the function
disabled
, priority is given to the current harmonic filtering and power factor correc-
tion and overload balancing are penalised.
Table 24: Order of priorities
Priority
Order of priorities function
Disabled
Enabled
+
Harmonic filtering
Phase balancing
Power factor correction
-
Phase balancing
Power factor correction
Harmonic filtering
Reactive
Enable this function so that the device compensates the reactive energy or corrects the displacement
power factor, cos
Φ
.
Press the
key to access the next configuration step
Press the
key to access the main screen of the device without saving the configuration values
Summary of Contents for AFQm-3WF-030M-480
Page 1: ...INSTRUCTION MANUAL Active Parallel Multi Function Filter AFQm M217B01 03 21A...
Page 2: ...2 AFQm Instruction Manual...
Page 111: ...111 Instruction Manual AFQm 608 812 1755 665 465 1890 Figure 108 Dimensions Cabinet type AFQm...
Page 113: ...113 Instruction Manual AFQm 14 CE CERTIFICATE...
Page 114: ...114 AFQm Instruction Manual...
Page 115: ...115 Instruction Manual AFQm...