ENGLISH
9
2.5.2 INSTALLING THE OUTLET PIPES
41
5
M
ax
A
C
41
5
M
ax
A
NOTE!
The center of the appliance
flue terminal is 415 mm
from the floor level.
NOTE!
When adjusting the pipe length, please notice
that the pipe will enter 1 3/8” (35 mm) into the
appliance flue terminal, and will have to be
calculated into the planning of your installation.
NOTE!
When installing the pipe vertically, straight up
from the appliance, please notice that the
minimum distance from the wall to the toilet
must be 11 1/32” (280mm).
NOTE!
The Original Cinderella Installation Kit includes
5 x 41 31/32” (1066 mm) pipes to be used on the
outlet installation, the pipes are delivered with
socket and gasket for simple installation. When
installing the pipe on the outer wall, you will have
to enter the pipe from the external to the inside.
Cut the pipe to the desired length, use the part
with the socket and gasket between the elbow
bend and the appliance, the part without a
socket should be used on top of the flue pipes to
connect to the flue cap.
DIAMETER VENT PIPE
OUTLET DIRECTION
REFERENCE
BENDS
MAXIMUM PIPE LENGTH
IMPERIAL
METRIC
IMPERIAL
METRIC
4 21/64”
110mm
Horizontal flue pipe
C
(Not allowed)
39 3/8”
1.0m
4 21/64”
110mm
Vertical flue pipe
A
None
39 3/8”
5.0m
16 11/32”
4 3/8”
415 mm
Ø 111mm
1 3/8”
35 mm
11 1/32”
mm
280