10
NOTE!
• The pipe must always be installed vertically above the
roof and extend at least 23 5/8” (600 mm) above the
roof surface. If the outlet air pipe is to be enclosed (e.g.
using metal siding), make sure that the end of the pipe
extends at least 15 3/4” (400 mm) above the enclosure.
• If installed where snow is likely to accumulate it might be
necessary to extend the pipe further, and to secure ac
-
cordingly. Keep in mind not to extend beyond maximum
allowed pipe length
NOTE!
Cinderella supplies a specially designed siphon that
fits onto the elbow provided in the installation kit. If
installation is done from the interior, you will need
to connect the siphon to the elbow-piece to prevent
condensation and rainwater to drain onto the floor.
Failure to collect the condensation and emptying it
regularly, may result in damage to the floor.
60
0
m
m
23 5/8”
40
0
m
m
15 3/4”
NOTE!
The systems flue terminal is designed for connecting 110 mm PP quality pipes with an
inner diameter of no less than 102 mm (4 inches). The pipe is to enter 35 mm (1 3/8”) onto
the toilet flue terminal. Do not use excessive force when connecting the pipe, as this may
damage the system. The ventilation must be attached to the appliance by fastening the
gear clamp around the gasket and pipe. Ensure that the pipe is firmly connected to the
appliance before tightening the gear clamp.
2.5.3 INLET AIR TERMINAL
It is required to have an inlet air vent in accordance with manufacturer specifications, this to ensure adequate air
circulation and oxygen required for proper incinration. T
he Cinderella Original Accessory Kit includes a flue specially
designed air vent designed for optimal flow and increased product efficiency.
The air inlet vent should preferably
be installed as close to the Cinderella toilet as possible, to ensure a good air supply to the toilet and reduce the
environmental impact in the toilet room. It is important that there are no other air-dependent installations used at
the same time as the toilet, e.g. an extractor fan or fireplace. The Cinderella GAS NA toilet draws air mainly from the
underside of the toilet. It is therefore possible to have the air intake underneath the toilet. This allows you to insulate
the air as much as possible in the toilet and minimise the environmental impact in the toilet room.
50 mm
NOTE!
If the installed air vent has an adjustable opening, always
make sure to leave it open by a minimum of 50 mm (two
clicks) when operating the toilet.
NOTE!
• The inlet vent’s minimum dimensions must be 160 mm (diameter) / 201 cm²
• The vent must be open at all times when using the appliance. Remember to clean the
vent at regular intervals.
•
Make sure that there is no conflict between the toilet’s air supply and other installa
-
tions, such as a fireplace or extractor fan.
•
Do not use a separate ventilation fan or similar to extract air from the room where the
toilet is installed when using the Cinderella GAS NA toilet.
• If you have open ventilation under the toilet, it may be advisable to use a mesh over the
hole to keep insects and vermin from entering the toilet. Make sure that the mesh is
not too fine, minimum 5 mm mesh, smaller mesh will impede the air flow.