2.4 INSTALLATION SPECIFICATIONS
2.4.1 SPECIFICATIONS PARTS AND MATERIALS
NOTE!
The Cinderella GAS NA system is required to be vented with with 636-certified pipes and
in accordance with the Canadian Gas Code when installed in Canada. Contact your local
tradesman for further instructions.
ITEM
SPECIFICATIONS
Ventilation pipes
The toilet must be installed with straight hard pipes with a smooth inner surface,
preferably of a 636-rated PP quality, with a minimum temperature tolerance of 90° Celsius
(194° Fahrenheit). Do not use any flexible ducts or pipes when installing the Cinderella GAS
NA toilet.
To ensure proper airflow we reccomend you install the system with 110 mm
pipes with a minimum inner diameter of 102 mm (4 inches), it`s an absolute
requirement to use pipes with inner diameter of no less than 95 mm (3 3/4 inches) when
installing the Cinderella GAS NA incineration toilet to ensure proper air flow and system
functionality.
Elbow (Outlet air) Cinderella GAS NA is required to be installed with a smooth curved elbow that minimizes
the restriction of the air flow. We strongly recommend using the Original Cinderella Elbow
87° w/ drain. Consult your nearest Cinderella dealer if you consider using any other bend
for this appliance, as any restriction in airflow can cause system malfunction.
Flue Terminal Cap You must install a chimney cap on top of the outlet pipe for your Cinderella GAS NA
appliance. We recommend that you use the supplied chimney cap when installing your
system. If you need to use another chimney cap, make sure you consult your nearest
Cinderella dealer. Too much restriction in the chimney cap could cause the system to
malfunction.
CINDERELLA ORIGINAL INSTALLATION KIT QTY
1
Male-Female 1066 mm flue pipe
5
2
Wall mount rod
3
3
Support clamp
3
4
Elbow 87 w/drain
1
5
Threaded rod 30 mm
3
6
Connector ring
5
7
Gear clamp
1
8
Ball valve siphon
1
CAUTION!
The Cinderella GAS NA toilet must have its own outlet air pipe and it is not permitted to
install Cinderella GAS NA ventilation with the use of the following:
• Wind fan or similar as a replacement for the chimney cap
•
Flexible ducts or pipes.
• Pipes with inner diameter less than 95 mm (3 3/4”) .
• Bends in addition to the T-bend.
•
Never use a fine mesh net in the ventilation pipe as this might restrict the airflow in the
system.
2.3 ORIGINAL INSTALLATION PACKAGES FOR YOUR CINDERELLA TOILET
Cinderella Original Installation Kit:
This complete set includes pipes and necessary parts for completing the
installation of your toilet in accordance with the Canadian Gas Code and ULC-S636 requirements. The installation
kit includes 5 x 110mm 636 certified PP quality pipes with accompanying locking system, and pipe clamps
for completing the outlet ventilation. The kit also provides an optimized elbow for increasing the system flow
rate and incineration efficiency, and a ball valve siphon for safeguarding against any condensation within the
ventilation pipes.