Air pressure insufficient
Note: To enable this function, the
barometer should have an electric
contact
Check the air pressure of the machine
Check transducer fault
Note: To check the transducer, riot is
necessary or connect a transducer fault
connection wire
Check whether the transducer is
abnormal, whether the parameter
setting is reasonable, whether the
connecting wire is loose
Check broken cloth
Note: Check is available only if a cloth
break probe is installed.
Check cloth break status and solve
the problem
--
An external low-voltage load short
circuit, external low-voltage load
power supply is cut off
Check whether the AC 12 and 24
volts of the power supply board is
normal
--
Over-speed error, when the machine
speed exceeds the set value (Figure
21) , the machine will report an error
Make sure whether the speed limit is
reasonable, whether the machine
speed regulation is normal
In case of upper and mid section yarn break, cloth break, oil insufficiency, air pressure insufficiency, the machine
still needs jogging function, needs the forcing key, the prompt
on the screen becomes yellow. If continually
use the forcing key to make the indicator lamp flashes, then the machine enter the forced mode, and the poser supply
to the yarn feed lamps is cut off to prevent over-current when many of the yarn feed lamps are lit.. You can press the
forcing key again to exit the forced or super forced state.
If the whole following warning menu is displayed, the machine may has an internal malfunction.
(Fig. 73)
When the communication between the main machine of the driving part of the electrical panel has any problem, the
alarm menu will appear as shown in the above diagram. At this time turn off the machine's power, check whether the
PA cable (20-pin ribbon cable) is broken, whether it is tightly connected with the sockets of the host and the power
Group
Port is not connected
Know/EMT