![chromasens 3DPIXA Manual Download Page 71](http://html1.mh-extra.com/html/chromasens/3dpixa/3dpixa_manual_2605699071.webp)
6 Setting up the 3D scanner system
3DPIXA
CD40131 Version 1
71 / 99
15. In the
Camera Settings
select
White control
in the
Camera parameter
folder.
16. Check the values in the
Current White reference levels
field:
Fig. 42: White reference values
The current white reference levels should be between 780 and 820.
17. Make the following settings and save the settings in the volatile memory of the camera:
Parameter
Setting
Value
Camera Parameter
–
Gain and reference settings
Enable continuous white
control
Disabled
Update start gain with
current gain values
Enabled
Tab. 21: Adjusting the start gain values
Now the values in the
Start gain values
field match with the values in the
Current
camera gain values
field.
18. Save the settings in the non-volatile memory of the camera by selecting the appropriate
toolbar icon or by pressing the F10 key.
The camera will start with the start gain values.
Due to lens vignetting (shading), the image may have inhomogeneous light distribution. This
will be improved with the shading (flat field) correction (see chapter 6.14, p. 77).