5.3.2.17 SYNCHRONOUS Subsystem
:SYNChronous
:CHANnel
SP
<NRF+>
:RUN
:TYPE
SP
OFF / 0
ON / 1
NONE / 0
MASTER / 1
SLAVE / 2
SP
SYNChronous:CHANnel
Type:
All Channels
Description:
Set the specified channel to T1 & T2 in sync dynamic mode for
parallel loading.
Setting Syntax:
SYNChronous:CHANnel<space><NRf+>
Setting Parameters:<NRf+>, 1 ~ 10
Setting Example: SYNC:CHAN 1
Set the specified channel to "1".
SYNC:CHAN MAX
Set the specified channel to "10".
SYNC:CHAN MIN
Set the specified channel to "1".
SYNChronous:RUN
Type:
All Channels
Description:
Set all electronic loads to “ON” in sync. parallel run.
Setting Syntax:
SYNChronous:RUN<space><NRf>
Setting Parameters:<NRf>, OFF(0
)
,
ON(1)
Setting Example: SYNC: RUN ON Set the load to “ON” on sync. parallel.
SYNC: RUN OFF Set the load to “OFF” on sync. parallel.
SYNChronous:TYPE
Type:
All Channels
Description:
Set the specified mainframe to master or slave for sync. in parallel
run.
Setting Syntax:
SYNChronous:TYPE<space><NRf>
Setting Parameters:<NRf>, NONE(0), MASTER(1), SLAVE(2)
Setting Example:
SYNC:TYPE MASTER
Set the mainframe to master for sync.
in parallel run.
SYNC:TYPE SLAVE
Set the mainframe to slave for sync. in
parallel run.
SYNC:TYPE NONE
Disables the mainframe to sync.