Local Operation
4-43
Select None / Master / Slave for parallel mode
. Set the specified module to none, master
or slave for parallel run.
NONE:
Disable the MASTER/SLAVE control function.
MASTER:
Used as the master for the parallel group and this is the only one controlled by
front panel or PC in this group. Also tell the slaves how many current they
should sink. Slave Model: 1 – 5 to setup the slave’s model to use in parallel.
NONE means not exist.
SLAVE:
Setup the load as slave.
[PARALLEL MODE]
MODE
: MASTER
INITIAL
: OFF
To leave out of the Parallel edit page of system configuration, you need to press
and
simultaneously to go back to the page of system configuration.
4.7.5 Setup of Synchronous Dynamic Mode
The following is Operation Flow:
CONFIG
SYNC.
Mode
Mode?
NONE
MASTER
SLAVE
When Synchronous Dynamic Mode is set to ON, the Load on/off is controlled by
key
on the any module of the Mainframe. Under other circumstances the Load on/off is
individually and simply controlled by
key on the module.
In the page of system configuration, turn the Rotary knob to change the display value to 5,
then press
key into Synchronous Dynamic Mode page of system configuration.
Select None / Master / Slave for Synchronous Dynamic Mode
. Set the specified module
ENTER
LOAD
LOAD
ENTER
ADVA