Programmable DC Electronic Load 63600 Series Operation & Programming Manual
5-56
DIGitizing:INITiate
Type:
Channel-Specific
Description:
Start the digitizing function to wait trigger signal.
Setting Syntax
DIGitizing:INITiate
Setting Parameters: None
Setting Example: DIG:INIT
Initial digitizing function.
Query Syntax:
None
Return Parameters:None
Query Example:
None
DIGitizing:SAMPling:POINt
Type:
Channel-Specific
Description:
Set the sampling points for digitizing function.
Setting Syntax:
DIGitizing:SAMPling:POINt<space><NRf+>
Setting Parameters:<NRf+>, 1 ~ 15,000, Resolution = 1, Unit = None
Setting Example:
DIG:SAMP:POIN 500
Set sampling points = 500
DIG:SAMP:POIN MAX
Set sampling points = maximum
value.
DIG:SAMP:POIN MIN
Set sampling points = minimum
value.
Query Syntax:
DIGitizing:SAMPling:POINt?[<space><MAX | MIN>]
Return Parameters:<NR1>, [Unit = None]
Query Example:
DIG:SAMP:POIN?
DIG:SAMP:POIN? MAX
DIG:SAMP:POIN? MIN
DIGitizing:SAMPling:TIME
Type:
Channel-Specific
Description:
Set the sampling time for digitizing function.
Setting Syntax:
DIGitizing:SAMPling:TIME<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 2
μs ~ 40ms, Resolution = 2μs, Unit = Second
Setting Example:
DIG:SAMP:TIME 0.02
Set sampling time = 20ms
DIG:SAMP:TIME 20ms
Set sampling time = 20ms
DIG:SAMP:TIME MAX
Set sampling time = maximum
value.
DIG:SAMP:TIME MIN
Set sampling time = minimum
value.
Query Syntax:
DIGitizing:SAMPling:TIME?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Second]
Query Example:
DIG:SAMP:TIME?
DIG:SAMP:TIME? MAX
DIG:SAMP:TIME? MIN
DIGitizing:TRIGger[:STATe]
Type:
Channel-Specific
Description:
Set the software trigger for digitizing function.
Setting Syntax
DIGitizing:TRIGger[:STATe]<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, OFF(0), ON(1)
[Unit = None]
Setting Example: DIG:TRIG ON
Set trigger state to ON.
DIG:TRIG 0
Set trigger state to OFF.
Query Syntax:
DIGitizing:TRIGger[:STATe]?
Return Parameters:<CRD>, IDLE, PRE_TRIG, WAIT_TRIG, POST_TRIG
Query Example:
DIG:TRIG?