Programmable DC Electronic Load 63600 Series Operation & Programming Manual
4-46
8.INFORMATION
1
636XX-XX-XX
G_FW: x.xx
G_PCB: xx.xx
G_HDL: xx.xx
A_FW: x.xx
A_PCB: x.xx
A_HDL1: x.xx
A_HDL2: x.xx
C1_FW: x.xx
C1_PCB: x.xx
C1_HDL1: x.xx
C1_HDL2: x.xx
9.DIGITIZING
SAMPLING_TIME: 40.000ms
SAMPLING_POINT: 4096
TRIG_SOURCE: LOAD_ON
TRIG_POINT: 2000
DIGI: INITIATE
Note:
FW: Firmware version, PCB: PCB version; HDL: CPLD & FPGA version; G, A, C1, C2 (63610-80-20) represents the PCB
name in the module respectively.
4.7.7 Display Model Information
In the page of system configuration, turn the Rotary knob to change the display value to 8,
then press
key into Display Model Information page of system configuration.
Display the Load model and serial number
. Display the model number of Load module. It
is a fixed value and cannot be selected or changed.
63630-80-60
[636308000066]
Display C board F/W version, PCB version and HDL version
.
Display firmware version,
PCB version and hardware description language version of C board. It is a fixed value and
cannot be selected or changed.
C_F/W : X.XX
C_PCB : X.XX
C_HDL1: X.XX
C_HDL2: X.XX
Then the display will go to the first editing page again.
To leave out of the Display Model Information page of system configuration, you need to
press
and
simultaneously to go back to the page of system configuration.
ENTER