![background image](http://html.mh-extra.com/html/christie/rpmsp-d120u/rpmsp-d120u_setup-manual_2604059027.webp)
Section 2: Installation & Setup
RPMX-RPMSP-D120U & RPMSP-D275U Setup Guide
2-19
020-100038-02 Rev. 1 (09/08)
Figure 2.23. Ethernet Network
SETTING THE PROJECTOR’S IP ADDRESS
: Upon connecting to most Ethernet
networks each projector’s factory default IP address of 0.0.0.0 triggers the
network’s DHCP (Dynamic Host Configuration Protocol) server function to
automatically assign an IP address that is valid and unique for use on that
network. Depending on the network, this DHCP-assigned IP address usually
remains stable for a single session, but may change with subsequent power-ups
and logins. On some networks, the address will remain stable from session to
session. In all cases, the projector’s IP address and port appear in the
Status
menu
as well as the
Ethernet Settings
submenu.
Note that if a projector’s IP address is anything
other
than 0.0.0.0 (shown as
000.000.000.000 in the
Ethernet Settings
menu) upon connection to an Ethernet
network, or if DHCP is not available on the network, the automatic DHCP server
function for supplying a valid and unique IP address to the projector is disabled.
Instead, a specific and static IP address must be defined in projector memory—
enter the new address in the
Ethernet Settings
submenu, or send to the projector
via a serial command. The IP address will be in effect until it is changed again, or
until the DHCP checkbox is re-enabled for use with a DHCP server on the
network.
CHANGING THE PORT#:
On some Ethernet networks, you may be required to
change the firewall restrictions from the default value (3002). If so, enter a new
port number in the
Ethernet Settings
menu or include the new port# in an XIP
serial command sent to the projector. It is highly recommended not to use a port#
below 1000, as these ports are typically reserved for and used by common IP
applications.
SUBNET MASK AND DEFAULT GATEWAY:
The Subnet Mask and Default Gateway
are automatically assigned when DHCP is enabled. If a static IP is being used, it
must be assigned before the subnet mask. The Default Gateway is an optional
router device used to send and receive data outside the subnet.
ArtNet INTERFACE SETTINGS:
Refer to
Section 3.6 – Adjusting System
Parameters and Advanced Control, System Configuration – Communication
for additional information about ArtNet settings.