Serial Command Reference
Mirage WQ-L User Manual
77
020-101372-01 Rev. 1 (04-2014)
Auto Shutdown (ASH)
Baud Rate (BDR)
ASH
CONTROL GROUP:
Saved
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
When Auto Shutdown Mode has been selected, and no projector activity has been seen for the activation time-out
period, the projector will enter a Power Saving mode in which the lamps will dim and the shutter close. If this
condition persists for an additional time-out period the projector will automatically go to standby. The presence of
any activity within this is combined interval will cancel Auto Shutdown and return the projector to normal
operation.
Subcode
<No Subcode >
Description of Use
Enable or disable Auto Shutdown Operation.
SBTO
Set the uninterrupted time-out period that must elapse before
projector will enter Standby Mode (The second time-out period
or Standby time-out).
ALTO
Set the uninterrupted time-out period that must elapse time of
activity loss until Auto Shutdown is activated (The first time-
out period or Activation time-out).
Examples:
(ASH 1) Turns ON Auto Shutdown Mode.
(ASH 0) Turns OFF Auto Shutdown Mode.
(ASH+SBTO 10) Sets standby time-out to 10 minutes.
(ASH+ALTO 10) Sets source activity loss time-out to 10 minutes.
BDR
CONTROL GROUP:
Preference
SUBCLASS:
Power Down
ACCESS LEVEL:
Advanced
Description
Set the baud rate for a serial communications port. For RS232 IN and RS232 OUT, the default is 115200. For
RS422, the default is 19200. The default communications settings for all ports is eight data bits, no parity. Valid
baud rates, with the values to select them, are:
0 = 1200
1 = 2400
2 = 9600
3 = 19200
4 = 38400
5 = 57600
6 = 115200
Subcode
PRTA
Description of Use
Set the baud rate on port A (RS232 IN)
.
PRTB
Set the baud rate on port B (RS232 OUT)
.
PRTC
Set the baud rate on port C (RS422)
.
Examples:
(BDR+PRTA 6) Set baud rate on port A to 115200 bits per second.
(BDR+PRTA?) Get baud rate (BDR+PRTA!"115200").