Troubleshooting
Mirage WQ-L User Manual
59
020-101372-01 Rev. 1 (04-2014)
Status Display
Projector status is indicated by a single three-color LED adjacent to a two-digit status display. Refer
to the table below for a description of the variations that indicate operation status. A solid red LED
indicates a system error and the corresponding error code indicates what the error is.
Error Codes
If the status display window shows any of the codes in the table below you may need a Christie
accredited service technician to repair the component identified by the error code.
Error codes are displayed in a three-phase format:
• First two digits represent the component or error category
• Second two digits represent the specific problem
• Display off
This cycle repeats. The LED will be red while the error code is displayed.
Status
Two-Character Display
Description
Solid Yellow
Rotating
Warming up.
PR (Programming Time)
FS (Failsafe mode)
The projector is in Failsafe mode. See
— —
, static
Standby mode.
— —
, moving up and down
Brief cool down period.
Solid Green
• BO (Booting) when power first applied.
• B1 (Boot phase 1) starting main script
• B2 (Boot phase 2) starting projector code
• B3 (Boot phase 3) about to initialize
connections
SH (Shutter Mode)
LEDs are disabled to shutter the projector.
Flashing Green
Keypad command sent — command received.
Solid Red
System error.
See
blank
Rotating
Initializing hardware and performing Power
On Self Test.