Serial Command Reference
Mirage WQ-L User Manual
80
020-101372-01 Rev. 1 (04-2014)
Color Enable (CLE)
Data Logging (DLG)
3D Dark Interval (DRK)
Controls the time between frames when no image is being projected to the screen. Used for 3D
applications to determine the time that the shutter mechanism has to open or close between fields.
Keep at default value of zero for all other applications. Increasing this control will reduce the peak
brightness of the image.
Parameters
• Control Group: Preference
• Subclass: Power Up
CLE
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Up
ACCESS LEVEL:
Operator
Description
This control allows the three primary colors (red, green, and blue) to be turned ON or OFF separately. It is used
to look at the colors one at a time or in pairs when doing convergence, light measurements, etc. The list of values
for this command are:
0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
Subcode
<No Subcode >
Description of Use
Examples:
(CLE 1) Display red portion of image only.
(CLE 5) Display green and blue portion of image only.
(CLE 0) Display image normally (all primaries).
DLG
CONTROL GROUP:
Preference
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
Set data logging level.
0 = Minimal logging of activities. Logging system errors, warnings and 'events' (i.e. power ON/OFF, lamp ON/
OFF, user login/logout).
1 = Normal logging. Most activities logged - errors, warnings, events, and other info.
2 = Debug logging. All activities are logged.
Subcode
<No Subcode >
Description of Use
There are three levels for data logging.
Examples:
(DLG1) Set current logging level to 1.
(DLG?) Get current logging level. Response is (DLG!001).