Projector Health (HLT)
Test Pattern Grey (ITG)
Internal Test Pattern (ITP)
HLT
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
Any system health errors are placed on the troubleshooting queue. The queue, which contains the problems and
a suggested solution for each one, is read-only. All problems in the queue are read using their index number,
which starts from 0.
Problems are assigned priorities:
1 = Critical - Will result in failure to operate or shutdown
2 = High - Will result in significant loss of functionality but the projector may continue to run
3 = Low - Will result in minor loss of functionality which will not seriously affect projector
Subcode
LSOL
Description of Use
List solutions.
LALL
List one or all problems and solutions.
Examples:
(HLT?) Returns all queued problems.
(HLT? 3) Returns problem index 3 in the queue.
(HLT+LSOL? 4) Returns the solution hint for problem index 4 in the queue.
(HLT+LALL?) Returns all queued problems and their solutions.
(HLT+LALL? 3) Returns problem index 3 and its’ solution.
ITG
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Up
ACCESS LEVEL:
Operator
Description
Specify the grey level to use for the 'Grey' flat field internal test pattern. Range 0-1023. The level defaults to 512
on power up. This command is on available while the grey test pattern is being displayed.
Subcode
<No Subcode >
Description of Use
Example:
(ITG 512) Set test pattern grey to mid point.
ITP
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Up
ACCESS LEVEL:
Operator
Description
Puts a test pattern on the screen or queries the test pattern currently displayed. Select which test pattern to
display from the list:
0 = Off
1 = Grid
2 = Grey Scale 16
3 = White
4 = Flat Grey
5 = Black
6 = Checker
7 = 13 Point
8 = Color Bars
12 = Edge Blend
14 = Boresight