Serial Command Reference
Mirage WQ-L User Manual
96
020-101372-01 Rev. 1 (04-2014)
Advanced Color Setting (RGB)
Real Time Events (RTE)
RGB
CONTROL GROUP:
Preference
SUBCLASS:
Power Up
ACCESS LEVEL:
Operator
Description
Adjusts native projector color space by adjusting the LED power levels. This can be used when ColorLOC is
disabled or if ColorLOC is running in Native or Fixed mode. Care should be exercised when adjusting these
settings as it is possible to overdrive the LEDs and may cause the projector to perform a safety shutdown.
Subcode
CLRM
Description of Use
Color Mode. Selects:
1 = Native 4 = User preset 2
2 = EBU 5 = User preset 3
3 = User preset 1 6 = User preset 4
ROFR
Red part of red (0-4095)
GOFG
Green part of green (0-4095)
BOFB
Blue part of blue (0-4095)
RGBB
Controls overall brightness of LEDs (0-1000) percentage with
one decimal place
COPY
Copies color mode settings from an existing preset to the
current preset. Values:
1 = Copy from Native 4 = Copy from User 2
2 = Copy from EBU 5 = Copy from User 3
3 = Copy from User 1 6 = Copy from User 4
Examples:
(RGB+ROFR 128) Set Red of Red value.
(RGB+BOFB ?) Get Blue of Blue value.
(RGB+RGBB 500) Set overall brightness to 50%.
(RGB+CLRM 4) Select user preset 2.
(RGB+COPY 2) Copy EBU preset values to current preset.
RTE
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
Real time events allow custom user actions to occur based on a system trigger. There are various triggers in the
system such as power up, input change, errors, or based on time. Time can be absolute, (e.g. 12:00:00 on
December 25, 2008) or relative (e.g. 5 hours and 30 minutes from now).
Special Function keys can also be used as a trigger. An example would be pressing
F
UNC
+1
on the remote.
Events can also be connected to external hardware triggers via the General Purpose IO port (GPIO).
Events:
Single Occurrence Events:
(RTE T YYYY/MM/DD HH:MM:SS S "description" "command")
Daily Occurring Event:
(RTE T YYYY/MM/DD HH:MM:SS YYYY/MM/DD D R "description" "command")
Where the first date and time is the start date and occurrence time. The second date is the end date.
R is the "Repeat Every" interval i.e. repeat every R days