INST.No.INE-559-P1
-27-
CONT
PEAK
AL
A H
Tb
MEM
Sub display
9.10 Setting of device address
1) Press the SEL key couple of times from engineering mode
screen to display
"Adr"
shown on the right figure on sub
display.
2) Press
↑
key or
↓
key and change set value of device address.
Setting is completed by changing the numeric value.
3) It shifts to the next screen by pressing the SEL key.
9.11 Selection of communication speed
1) Press the SEL key couple of times from engineering mode
screen to display
"SPd"
shown on the right figure on sub
display.
2) Press
↑
key or
↓
key and change communication speed
types.
Setting is completed by changing.
3) It returns to the measurement screen by pressing the SEL
key.
[Device address]
CONT
PEAK
AL
A H
Tb
MEM
Sub display
Main display
・
Setting range is 1 to 32
・
Default setting is 1
・
Default setting is 9.6 (9600bps)
[Communication speed types]
9.6: 9600bps
19.2: 19200bps
38.4: 38400bps
57.6: 57600bps
115.2: 115200bps
[19200bps]
CONT
PEAK
AL
A H
Tb
MEM
[38400bps]
[57600bps]
[115200bps]
CONT
PEAK
AL
A H
Tb
MEM
CONT
PEAK
AL
A H
Tb
MEM
CONT
PEAK
AL
A H
Tb
MEM
[9600bps]
Main display
R e m a r k s