Instruction Manual
SMART-LIFT Electric Ceiling Lifts
30
12
LIMIT
RELAY
COMMON
13
RETRACT
LIMIT
RELAY
Closes set of internal dry contacts
when unit reaches full retraction.
14
EXTEND
LIMIT
RELAY
Closes set of internal dry contacts
when unit reaches full extension.
RATED FOR 1 AMP @ 24 VOLTS
WIRING THE RC-10
Connect white lead to terminal 1, red lead to terminal 2, and black lead to terminal 6.
Place jumper wire from terminal 2 to terminal 5
WIRING A MOMENTARY PUSH BUTTON
Connect terminals 9 & 5 with Jumper Wire. Connect Momentary Switch to terminal
10. Connect other line of Momentary Switch to terminal 6.
Summary of Contents for SL-100
Page 20: ...19 Instruction Manual SMART LIFT Electric Ceiling Lifts THIS PAGE INTENTIONALLY BLANK ...
Page 22: ...21 Instruction Manual SMART LIFT Electric Ceiling Lifts THIS PAGE INTENTIONALLY BLANK ...
Page 24: ...23 Instruction Manual SMART LIFT Electric Ceiling Lifts THIS PAGE INTENTIONALLY BLANK ...
Page 26: ...25 Instruction Manual SMART LIFT Electric Ceiling Lifts THIS PAGE INTENTIONALLY BLANK ...
Page 29: ...Instruction Manual SMART LIFT Electric Ceiling Lifts 28 This Page Intentionally Blank ...