Instruction Manual
1310 3012 02
63
CPS
4.11.3
Replacing the coolant
Drain
•
Completely drain the entire cooling system.
•
Used coolant must be disposed or recycled in accordance with laws and local regulations.
Flush
•
Flush twice with clean water. Used coolant must be disposed or recycled in accordance with laws and
local regulations.
•
From the Chicago Pneumatic Instruction book, determine the amount of GENCOOL EG required and
pour into the radiator top tank.
•
It should be clearly understood that the risk for contamination is reduced in case of proper cleaning.
•
In case a certain content of ‘other’ coolant remains in the system, the coolant with the lowest
properties influences the quality of the ‘mixed’ coolant.
Fill
•
To assure proper operation and the release of trapped air, run the engine until normal engine
operation temperature is reached. Turn off the engine and allow to cool.
•
Recheck coolant level and add if necessary.
Caution: do not top off when the engine is hot.