The remaining time is shown in the display:
Meanwhile the air receiver is depressurised. Switch the “ON/OFF” switch to the position “OFF”.
3.3.8
Shut downs
There are several parameters that are continuously watched. When one of these parameters exceeds its
specified limit the compressor will shut down immediately.
These parameters are:
•
Air discharge temperature too high
•
Low coolant level
•
Low fuel level
•
Engine faults (ENGINE FAULT INDICATION)
•
No communication engine-system (CAN LINK)
When the compressor is shut down because of exceeding a parameter setting (e.g. compressor
temperature) the display shows:
Restarting before the parameter is within its limits is impossible because of the parameter check in the
cranking procedure.
The display shows:
Do not push Emergency Stop during cool down process.