CPS 750
26
1310 3012 02
CPS
2.4.2
Air flow
Air drawn through the airfilter (AFce) into the compressor element (CE) is compressed. At the element
outlet, compressed air and oil pass into the air receiver/oil separator (AR/OS).
The check valve (CV) prevents blow-back of compressed air when the compressor is stopped. In the air
receiver/oil separator (AR/OS), most of the oil is removed from the air/oil mixture; the remaining oil is
removed by the separator element.
The oil collects in the receiver and on the bottom of the separator element.
The air leaves the receiver via a minimum pressure valve (MPV) which prevents the receiver pressure
from dropping below the minimum working pressure, even when the air outlet valves are open (specified
in section
8.3.2 Limitations
). This ensures adequate oil injection and prevents oil consumption.
A temperature sensor (TS) and a working pressure sensor (WPS) are comprised in the system.
Summary of Contents for CPS 750
Page 1: ...Instruction Manual for Portable Compressors English CPS 750 ...
Page 2: ......
Page 8: ...CPS 750 8 1310 3012 02 CPS ...
Page 86: ...CPS 750 86 1310 3012 02 CPS ...
Page 90: ...CPS 750 90 1310 3012 02 CPS 9 Dataplate ...
Page 92: ...CPS 750 92 1310 3012 02 CPS ...
Page 93: ......
Page 94: ...01 2009 1310 3012 02 ...