The warm-up time setting is 5 minutes max. There will be no warming up if the coolant temperature has
already reached 40 °C (104 °F).
The display will show:
After warming up the engine will run idle at an air receiver pressure of approx. 2 bar (29 psi). The engine
rpm is shown on the display.
The display will show:
3.3.6
Loading
By pressing the button “LOAD” the compressor will be loaded. The pressure will rise till it reaches the
setting.
If the button “LOAD” is pressed during the warm-up process the engine will first warm-up before
automatically switching to load.
The setting of the regulating valve with shut valves should be 2 bar (29 psi) higher
than the required working pressure.