4. Cleaning, Maintenance, Overhaul
• Remove the top of the filter element holder.
Fig. 4 - 8 Top of filter element holder removed
• Remove the new filter element from its packaging.
• Place the top and bottom of the holder in the new filter element and screw them together.
• Replace the filter element holder with the new filter element in the pressure filter housing.
• When connecting the pressure filter housing with the top of the filter element, ensure that the top of the filter element audibly
engages.
• Ensure that both O-rings (Fig. 4-5/1 and Fig. 4-5/2) do not slip and are not misplaced.
Fig. 4 - 9 Inserting the filter element holder into the pressure filter housing
• Screw the pressure filter housing finger-tight into the holder. Ensure that the housing is correctly aligned while screwing it in.
Fig. 4 - 9 Screwing the pressure filter housing in place
• Tighten the condensate collector into the holder.
• Plug in the mains cable.