APPENDIX
EN
INTELECT
®
RPW 2 USER MANUAL
ELECTROMAGNETIC COMPATIBILITY (EMC) TABLES (CONTINUED)
12.2 Electromagnetic immunity : Guidance and Manufacturer’s Declaration - Electromagnetic Immunity
Intelect RPW 2 is intended for use in the electromagnetic environment specified below. It is the responsibility of the customer or user to ensure
that the Intelect RPW 2 device is used in such an environment.
Immunity Test
IEC 60601 Test Level
Compliance Level
Electromagnetic Environment - Guidance
Electrostatic
discharge (ESD) to
IEC 61000-4-2
± 8 kV contact
± 15 kV air
± 8 kV contact
± 15 kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with
synthetic material, the relative humidity should be at least 30%.
Electrical fast transient/
bursts to
IEC 61000-4-4
± 2 kV
100 kHz repetition
frequency
± 2 kV
100 kHz repetition
frequency
Mains power should be that of a typical commercial or hospital environment.
Surges to
IEC 61000-4-5
± 1kV Line to Line
± 2kV Line to Earth
± 1kV Line to Line
± 2kV Line to Earth
Mains power should be that of a typical commercial or hospital environment.
Voltage dips
To IEC 61000-4-11
0% UT ; 0,5 cycle at 0°, 45°, 90°, 135°,
180°, 225°, 270°, 315°
0% UT ; 1 cycle and
70% UT ; 25/30 cycles
Single phase at 0°
0% UT ; 0,5 cycle at 0°, 45°, 90°, 135°,
180°, 225°, 270°, 315°
0% UT ; 1 cycle and
70% UT ; 25/30 cycles
Single phase at 0°
Mains power should be that of a typical commercial or hospital environment.
If the user of the Intelect RPW 2 device requires continued operation during
power mains interruptions, it is recommended that the Intelect RPW 2 device be
powered from an uninterruptible power supply or a battery.
Power frequency
(50/60 Hz)
magnetic field to
IEC 61000-4-8
30 A/m
30 A/m
Power frequency magnetic fields should be at levels characteristics of a typical
location in a typical commercial or hospital environment.
Note: UT is the a.c. mains voltage prior to application of the test level.
12.1 Electromagnetic emissions: Guidance and Manufacturer’s Declaration – Electromagnetic Emissions
Intelect RPW 2 is intended for use in the electromagnetic environment specified below. It is the responsibility of the customer or user to ensure
that the Intelect RPW 2 device is used in such an environment.
Emissions Tests
Compliance
Electromagnetic Environment - Guidance
RF emissions CISPR 11
Group 1
Intelect
®
RPW 2 uses RF energy for its internal function.
Additionally the Intelect RPW 2 contains a Bluetooth
®
radio module, which complies with the national
regulations. Therefore, its RF emissions are very low
and are not likely to cause any interference in nearby
electronic equipment. However, a separation distance
of 30 cm shall be maintained.
RF emissions to CISPR 11
Class B
Intelect RPW 2 is suitable for use in all establishments,
other than domestic and those directly connected to
the public low-voltage power supply network that
supplies buildings used for domestic purposes.
Harmonic emissions to
IEC 61000-3-2
complies with class
A requirements
Voltage fluctuations/flicker
emissions to IEC 61000-3-3
complies
Summary of Contents for Intelect RPW 2
Page 32: ...32 USER INTERFACE EN INTELECT RPW 2 USER MANUAL Select transmitter ...
Page 50: ...50 USER INTERFACE EN INTELECT RPW 2 USER MANUAL Delete one session ...
Page 55: ...55 USER INTERFACE EN INTELECT RPW 2 USER MANUAL Delete one protocol ...
Page 61: ...61 USER INTERFACE EN INTELECT RPW 2 USER MANUAL 4 Full screen image Close full screen mode ...