background image

15

C. In–line Activated Carbon Post Filter Assembly

Changing the In–Line Activated Carbon Post Filter:

1. Close the Feed Water Saddle Valve by turning fully 

clockwise. 

2. Close the Holding Tank Valve and then open the Dispensing 

Faucet to release the pressure. 

3. Remove the In–Line Activated Carbon Post Filter. Disconnect 

the used Post Filter by pressing in the connector’s collar and at 

the same time pulling the tube out of the fitting.

4. Firmly reconnect the polytubes to the new Post Filter. (Refer 

to Fig. 5). Make sure the tubing is pressed all the way in to 

create a pressure tight connection.

NOTE: If you want to pull the tubing out for some reason, 

push the ring around the tubing in and pull the tubing out.

5. Slowly open the Feed Water Saddle Valve. 

6. When water begins dripping out of the Faucet, in the 

following order, close the Faucet and open the Holding Tank 

Valve. When the Faucet is first opened, expect air and carbon 

fines (very fine black powder), from the new Post Filter to be 

rinsed out. This is normal for the first tank of water.

OUT

IN

In-Line  

Activated Carbon Post Filter

3/8" Blue

3/8" Blue

To

Dispensing

Faucet

Summary of Contents for CWQC50

Page 1: ...INSTALLATION OPERATION AND SERVICE MANUAL RO DRINKING WATER SYSTEM MODEL CWQC50...

Page 2: ...D VIEW AND PARTS LIST 18 CAUTION All individuals should take adequate precautions when changing the filter cartridges including protective gloves to avoid direct contact with the exhausted cartridges...

Page 3: ...ls picked up in the environment by the water are measured as Total Dissolved Solids TDS In the Reverse Osmosis process dissolved minerals are separated from the incoming water Feed Water to produce th...

Page 4: ...mbrane that has been rinsed for 24 hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water TABLE B RECOMMEND...

Page 5: ...5 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Page 6: ...6 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Page 7: ...7 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Page 8: ...Extra plastic tubing Low range air pressure gauge Bicycle hand air pump or compressor Small bottle of liquid chlorine bleach Graduated measuring cylinder Paper towels whisk broom and assorted clean u...

Page 9: ...a licensed plumber check with the local plumbing authority prior to installation In restricted under sink areas it may be easier to install the faucet first Allow adequate tubing lengths for any final...

Page 10: ...not supplied into the Faucet Base opening This will separate and orient the Toggle Wings Position the Faucet Base so that the arrows are pointing in the direction that the faucet handle will face Tigh...

Page 11: ...groove to prevent distortion of the tubing for larger tubing up to 5 8 OD use the large groove of the back plate Assemble and tighten the brass screw To pierce the tubing turn the Valve Handle fully c...

Page 12: ...n of a mounting plate 1 The mounting bracket will accept either 10 or 12 5mm mounting screws spaced on 7 1 8 18 1 cm centers Allow at least 2 5 08 cm of clearance beneath the filter housings to accomm...

Page 13: ...reconnect to the manifold plate 2 Start rinsing the system Slowly open the Feed Water Saddle Valve counterclockwise to its fully open position Open the faucet to allow air to escape while system is fi...

Page 14: ...ensing Faucet This will allow the manifold to be de pressurized so you can safely remove the old modules 2 Loosen and remove the Sediment Carbon Pre and Carbon Post Filter Modules 2 Press upward and t...

Page 15: ...lytubes to the new Post Filter Refer to Fig 5 Make sure the tubing is pressed all the way in to create a pressure tight connection NOTE If you want to pull the tubing out for some reason push the ring...

Page 16: ...water from Holding Tank and with the faucet open adjust the air pressure to 5 7 psig 35 48 kPa range Holding Tank Valve is partially closed Open Valve The Dispensing Faucet is out of adjustment or fau...

Page 17: ...ter overflows at the Dispensing Faucet Air Gap is blocked Clear Air Gap Rinse with vinegar for removal of calcium buildup Drain tubing is clogged Clear tubing Drain Clamp hole is misaligned Align with...

Page 18: ...18 EXPLODED VIEW 1 2 3 5 6 7 8 9 10 11 14 14 15 12 13 4 OUT IN S7206W JG In line Activated Carbon Post Filter 16...

Page 19: ...ner 1 12 S2116 6 Drain Restrictor 60 gpd 227 lpd 1 13 PK A6TEU4 MG Elbow Stem x 3 8 QC 1 14 S3551A 01 Sediment Carbon CS Module 2 15 S35715A 01 Membrane 50GPD Module 1 16 S7206W JG In line Activated C...

Page 20: ...d freezing or hot water All replacement filters and membranes must be Charger Water Treatment Products filters and membranes or the warranty is void If the unit is altered by anyone other than Charger...

Reviews: