background image

12

C. Drain Clamp Installation 

Choose the drain outlet location per Sec. III, C.5. The following 

are instructions for discharging into the sink drainpipe. 

1. Position the Drain Clamp on the sink drainpipe above the drain 

trap. Allow room for drilling. Tighten securely. 

2. Use a battery powered or properly grounded drill. Using the 

Clamp port as a drill guide, drill a 7/32" hole through the wall of 

the drainpipe. Do NOT penetrate the opposite side of the pipe. 

3. Locate the 3/8" Black Drain Tubing connected to the 

Dispensing Faucet. Route the tubing to the Drain Clamp and trim to 

length. 

NOTE: When cutting the polytube make clean, square cuts. Failing 

to do so could result in poor connections and possible leaks. 

CAUTION: The lowest point of the line should be the point of 

connection to the Drain Clamp. There should be no sag in the line 

as this may cause excessive noise as the reject water is flowing to 

drain. 

• Insert the tubing into the Drain Clamp. Make sure the tubing is 

pressed all the way in to create a pressure-tight connection. 

NOTE: If you want to pull the tubing out for some reason, push the 

ring around the tubing in and pull the tubing out.

D. Manifold Assembly Instructions 

Locate the site per Sec. III, C.3. Various installation sites will require different types of mounting fasteners; be sure the 

fastener selected will provide a firm, solid mounting. A support panel may be necessary on thin cabinet walls or to span 

between wall studs on particleboard or drywall.

Do not drill through exterior cabinet walls or leave sharp wood screw points exposed in readily accessible cabinet interiors. 

The proximity of a dishwasher or a trash compactor may require special fabrication of a mounting plate. 

1. The mounting bracket will accept either #10 or #12 (5mm) mounting screws spaced on 7 1/8" (18.1 cm) centers. Allow 

at least 2" (5.08 cm) of clearance beneath the filter housings to accommodate filter changes. Mark the two locations (the 

bracket can be used as a template). Install the screws and tighten them until the heads are about 5/8" from the wall.  

2. Locate the ¼" Red Feed Water Tubing. Remove the red plug from the fitting labeled “In” on the manifold and insert the 

tubing. Reference the special supplement sheet in the carton for proper connection of all tubing and removal of plugs. 

Run the tubing along its course to the Feed Water Saddle Valve, trim to length. To the end of the red polytube install the 

Compression Nut, the Plastic Ferrule, and the Insert. Connect to the Feed Water Saddle Valve. 

3. Locate the ¼" Black Drain Tubing connected to the Dispensing Faucet. The end of the Black Drain Tubing that should be 

inserted into the “Drain” port on the manifold will have a 

drain restrictor

 

in it. Remove the black plug from the fitting 

labeled “Drain” on the manifold and insert the tubing. Allow the tubing to relax, then press firmly again to insure proper 

seating. 

4. Locate the 

3

8

" yellow tubing, remove the yellow plug from the fitting labeled "Tank" on the manifold and insert the tubing. 

5. Locate the 

3

8

" Blue Product Water Tubing connected to the Dispensing Faucet. Firmly press one end into the elbow labeled 

"faucet". The fittings will grab the tubing and seal it in place. Make sure the tubing is pressed all the way in to create a 

pressure tight connection.  

NOTE: If the tubing is to be removed from the fitting for some reason, push the ring around the tubing in and pull the tubing 

out. 

6. Hang the Manifold Assembly on the mounting screws and tighten. DO NOT OVERTIGHTEN.

1/4" Nut

Drain Pipe

Drain Clamp

Back Plate

Drain Clamp

Front Plate

1/4" Screw

Black Drain 

Tubing

Summary of Contents for CWQC50

Page 1: ...INSTALLATION OPERATION AND SERVICE MANUAL RO DRINKING WATER SYSTEM MODEL CWQC50...

Page 2: ...D VIEW AND PARTS LIST 18 CAUTION All individuals should take adequate precautions when changing the filter cartridges including protective gloves to avoid direct contact with the exhausted cartridges...

Page 3: ...ls picked up in the environment by the water are measured as Total Dissolved Solids TDS In the Reverse Osmosis process dissolved minerals are separated from the incoming water Feed Water to produce th...

Page 4: ...mbrane that has been rinsed for 24 hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water TABLE B RECOMMEND...

Page 5: ...5 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Page 6: ...6 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Page 7: ...7 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Page 8: ...Extra plastic tubing Low range air pressure gauge Bicycle hand air pump or compressor Small bottle of liquid chlorine bleach Graduated measuring cylinder Paper towels whisk broom and assorted clean u...

Page 9: ...a licensed plumber check with the local plumbing authority prior to installation In restricted under sink areas it may be easier to install the faucet first Allow adequate tubing lengths for any final...

Page 10: ...not supplied into the Faucet Base opening This will separate and orient the Toggle Wings Position the Faucet Base so that the arrows are pointing in the direction that the faucet handle will face Tigh...

Page 11: ...groove to prevent distortion of the tubing for larger tubing up to 5 8 OD use the large groove of the back plate Assemble and tighten the brass screw To pierce the tubing turn the Valve Handle fully c...

Page 12: ...n of a mounting plate 1 The mounting bracket will accept either 10 or 12 5mm mounting screws spaced on 7 1 8 18 1 cm centers Allow at least 2 5 08 cm of clearance beneath the filter housings to accomm...

Page 13: ...reconnect to the manifold plate 2 Start rinsing the system Slowly open the Feed Water Saddle Valve counterclockwise to its fully open position Open the faucet to allow air to escape while system is fi...

Page 14: ...ensing Faucet This will allow the manifold to be de pressurized so you can safely remove the old modules 2 Loosen and remove the Sediment Carbon Pre and Carbon Post Filter Modules 2 Press upward and t...

Page 15: ...lytubes to the new Post Filter Refer to Fig 5 Make sure the tubing is pressed all the way in to create a pressure tight connection NOTE If you want to pull the tubing out for some reason push the ring...

Page 16: ...water from Holding Tank and with the faucet open adjust the air pressure to 5 7 psig 35 48 kPa range Holding Tank Valve is partially closed Open Valve The Dispensing Faucet is out of adjustment or fau...

Page 17: ...ter overflows at the Dispensing Faucet Air Gap is blocked Clear Air Gap Rinse with vinegar for removal of calcium buildup Drain tubing is clogged Clear tubing Drain Clamp hole is misaligned Align with...

Page 18: ...18 EXPLODED VIEW 1 2 3 5 6 7 8 9 10 11 14 14 15 12 13 4 OUT IN S7206W JG In line Activated Carbon Post Filter 16...

Page 19: ...ner 1 12 S2116 6 Drain Restrictor 60 gpd 227 lpd 1 13 PK A6TEU4 MG Elbow Stem x 3 8 QC 1 14 S3551A 01 Sediment Carbon CS Module 2 15 S35715A 01 Membrane 50GPD Module 1 16 S7206W JG In line Activated C...

Page 20: ...d freezing or hot water All replacement filters and membranes must be Charger Water Treatment Products filters and membranes or the warranty is void If the unit is altered by anyone other than Charger...