I N S T A L L A T I O N
Plumbing Requirements
¾
WATER SUPPLY – Hot and Cold Water should be supplied by ½” or ¾” water
lines, with the ¾” being the preferred method.
¾
DRAINS – A 1-1/2” minimum waste
connection is required. If equipped, the
scrapping sink typically has a 1-1/2” NPS
connection, while the wash, rinse, and
sanitize sinks typically have a 2” NPS
connection.
Pump
Pipe this connection
to floor drain
¾
PUMPS – The wash tank pumps will need
to be piped to a floor drain. This uses a ½”
NPT connection.
Bottom View of Pump Assembly
Electrical Requirements
WARNING
– Electrical Hazard – May result in electrical shock, burns, or death
¾
POWER – The power requirements for your unit are listed on the serial plate
located at the rear of the control panel. In the case of a control panel mounted on
top of the backsplash, the serial
plate will be located on the
inside of the control panel lid.
DELUXE
Taskmaster PP3
¾
CONNECTION – The single
point electrical connection is
located on the 20 amp fuse
block which is located inside the
control panel. See wire diagram
for details.
¾
POWER SOURCE – A dedicated service panel is required and should be located
on the wall or behind the control panel within 10 feet of the unit.
To ensure service reliability and safety, use water tight connections and the proper wire
gauge. A wire diagram is located inside the control panel lid and also at the back of this
manual.
Obey local, state, and national regulatory agency requirements when installing
electrical connections to this unit.
49
Summary of Contents for Taskmaster PP-3
Page 2: ...Left Blank This Page Intentionally ...
Page 12: ...O P E R A T I O N I N S T R U C T I O N S 11 NOTES ...
Page 48: ...C O N T R O L P A N E L S 47 NOTES ...
Page 52: ...M A I N T E N A N C E 51 NOTES ...
Page 63: ...P A R T S L I S T 62 NOTES ...
Page 64: ...P A R T S L I S T NOTES 63 ...
Page 65: ...P A R T S L I S T NOTES 64 ...
Page 66: ......